↗ krayer.de
DEEN
Discuss a UL project ↗
Your project. Your route to North America.

UL 508A.
Krayer builds to UL 508A under the Panel Shop Program.UL Listing Mark on the panel.

Krayer manufactures industrial control panels in the UL 508A Panel Shop Program as well as panels for applications under UL 698A and UL 1203. Eligible panels built in accordance with the applicable UL requirements can bear the UL Listing Mark. UL monitors compliance with the program requirements. The mark applies to the labeled control panel, not automatically to the entire machine.

Since 1989Krayer Systemtechnik
UL 508A · UL 698A · UL 1203UL control panels
USA · CanadaUL and CSA C22.2 No. 286 solutions
Offener UL-Schaltschrank von Krayer Systemtechnik
UL expertiseSince 2011
One partner, clear stepsFrom control panel to operation
KRAYER SYSTEMTECHNIK  /  NORTH AMERICA PROJECT PATH
Since 1989Krayer Systemtechnik
UL Panel Shop ProgramIndustrial control panels built to UL 508A
UL 698A · UL 1203For specialized applications
CSA C22.2 No. 286Equivalent to UL 508A and UL 698A
Interactive project path

Where are you in your North American project?

Three short choices help establish an initial scope for discussion. Then enter your contact details to open an email draft with your answers and project information.

Step 1 of 4

Where will you export?

Select the destination market for your machine or system.

The Krayer difference

Control panel manufacturing to UL 508A. UL Listing Mark on the control panel.

Krayer participates in the UL 508A Panel Shop Program. The program allows participating panel builders to mark eligible control panels under UL requirements. UL regularly monitors compliance with the program. The mark applies to the panel, not automatically the whole machine. Krayer’s UL and CSA C22.2 No. 286 evidence is publicly available.

Discuss your UL project with Krayer ↗
⌁
UL Listing Mark on the control panel

Krayer manufactures panels in the UL 508A Panel Shop Program. Eligible panels may be marked according to the program rules. UL monitors compliance through follow-up inspections.

↗
CSA C22.2 No. 286 certification

Krayer manufactures control panels to applicable CSA C22.2 No. 286 requirements. Eligibility for a CSA C22.2 No. 286 mark depends on product, application and target market.

◷
Project support as required

Available support may include UL-related services, export logistics, electrical installation and commissioning.

◇
UL experience since 2011

Krayer Systemtechnik was founded in 1989 and has worked with UL requirements since 2011.

UL services for machine builders

Engineering, control panel manufacturing and project support for North America.

Krayer combines technical control panel design with complementary services for deployment of machinery in the U.S. and Canada. The scope is agreed for each application.

01 / UNDERSTAND↗

Project and destination market

Machine, installation location and project phase as a shared starting point.

02 / ASSESS↗

UL control panel manufacturing

Engineering, production and documentation for the agreed application.

03 / SUPPORT↗

UL-related services

Pre-field evaluation, electrical installation and commissioning where needed.

04 / PLAN AHEAD↗

Logistics and on-site services

Discuss packaging, shipping, customs clearance or further assistance.

Selections in this cockpit do not replace a technical or standards assessment. Scope and responsibilities are agreed for each project.
Making complexity manageable

The right information for an initial technical discussion.

Destination, application, installation location and project status help Krayer assess relevant standards and control panel options. Add drawings and specifications in the inquiry form.

Prepare an inquiry ↗
Krayer · Standards and evidence

Certificates and technical evidence for industrial control panels

If you need a UL 508A industrial control panel for a machine in the U.S., the applicable requirements and actual certification scope must be assessed. Krayer publishes UL Customer Files for industrial control panels and specialized applications along with CSA C22.2 No. 286 and ISO 9001:2015 details. The identifiers shown here are from Krayer’s official certificate overview.

Industrial Control Panels · NITW

UL 508A

E474762

For industrial control panels built within the UL 508A Panel Shop Program.

View evidence on krayer.de ↗
CSA C22.2 No. 286 Certification number

CSA C22.2 No. 286

80216805

Evidence relating to the applicable CSA C22.2 No. 286 certification scope.

View evidence on krayer.de ↗
TÜV / quality management

ISO 9001:2015

Quality management

Krayer-published evidence of quality management processes in engineering.

View evidence on krayer.de ↗
Standards explained

UL Listing, CSA C22.2 No. 286 marks and standards for industrial control panels

The applicable standard depends on the machinery, application and installation location. Here is an initial overview.

What does “built to UL 508A” mean?

It indicates that the manufacturer applies UL 508A requirements. This statement alone does not prove participation in the UL Panel Shop Program or that the control panel bears a UL Listing Mark.

What is the difference between “built to UL 508A” and the Panel Shop Program?

“Built to UL 508A” describes the standard applied. Under the UL 508A Panel Shop Program, participating panel builders can mark eligible panels built in accordance with program requirements. Krayer lists certificate information showing UL Customer File E474762 for Industrial Control Panels (NITW).

FeatureBuilt to UL 508AUL 508A Panel Shop Program
EvidenceManufacturer statement and documentation of the standard appliedParticipation in the UL program for industrial control panel builders
UL Listing MarkNot established by this statement aloneMay be applied to panels meeting applicable program requirements
SurveillanceNo evidence of UL program participation from this wording aloneRegular UL follow-up inspections
ScopeManufacturer statement on panel constructionThe Listing Mark applies to the marked panel, not automatically the complete machine
What does the UL Listing Mark mean on a panel?

The mark identifies a control panel constructed and labeled under the applicable UL program requirements. UL does not pre-review every custom design. Manufacturers must follow and document UL 508A requirements, and UL monitors the program. NITW is the product category for industrial control panels.

Does a UL Listed panel mean the complete machine is approved?

No. The listing applies to the control panel within the specified certification scope. It does not automatically certify the complete machine. The competent Authority Having Jurisdiction (AHJ) reviews requirements at the site and may require more evidence.

What does CSA C22.2 No. 286 certification mean?

CSA C22.2 No. 286 certification means the relevant product has been assessed within a defined certification scope. CSA C22.2 No. 286 marks are used only on products covered by the applicable program. Always check the specific CSA C22.2 No. 286 standard and scope.

Can CSA C22.2 No. 286 certification also be relevant to the U.S. market?

Depending on the product standard and application, CSA C22.2 No. 286 certification may also be relevant for projects in the U.S. Acceptance depends on the applicable mark, standard, installation and AHJ requirements. Hazardous locations require separate assessment.

Does a Field Evaluation replace the UL Listing Mark?

No. A Field Evaluation is a separate on-site product assessment. A Field Evaluated Label may be applied following successful assessment, but it is not a UL Listing Mark and does not retroactively make the panel “UL Listed.”

When do UL 698A and UL 1203 apply?

UL 698A concerns certain control panels connected to hazardous locations via intrinsically safe circuits. UL 1203 relates to electrical equipment for classified hazardous locations. Applicability depends on the installation and classification.

What services does Krayer offer?

Krayer builds control panels in the UL 508A Panel Shop Program and for applications under UL 698A and UL 1203. Applicable standards and markings depend on product, location and target market. Depending on the contract, documentation, export support, electrical installation and commissioning may also be provided.

KRAYER · TECHNICAL KNOWLEDGE

UL 508A / CSA C22.2 No. 286 glossary: 40 technical terms explained

From SCCR and UL 508A to AHJ acceptance in the U.S.: concise definitions linked to Krayer’s existing technical wiki.

40 terms

Standards

UL 508A

Standard for industrial control panels in ordinary locations; addresses construction, components, wiring, protection and marking.

Read more on Krayer ↗
Standards

UL 698A

Standard for certain control panels with intrinsically safe circuits extending into classified locations while the panel is outside the hazardous area.

Read more on Krayer ↗
Standards

UL 1203

Standard for explosion-proof and dust-ignition-proof electrical equipment for specified hazardous locations.

Read more on Krayer ↗
Standards

CSA C22.2 No. 286

Standard for industrial control equipment, equivalent to UL 508A and UL 698A. The applicable certification scope should be checked for each project.

Read more on Krayer ↗
Standards

NFPA 70 / NEC

The National Electrical Code is a key U.S. electrical-installation code; the locally adopted edition governs.

Read more on Krayer ↗
Standards

NFPA 79

U.S. standard for electrical equipment of industrial machinery; distinct from the product standard for an industrial control panel.

Browse Krayer Wiki ↗
Standards

UL 50

Standard related to enclosures for electrical equipment; suitability depends on construction and environmental conditions.

Browse Krayer Wiki ↗
Standards

UL 2011 – Outline of Investigation for Machinery

UL investigation basis for machinery based on NFPA 79. Applicability should be checked for each project.

Browse Krayer Wiki ↗
Certification

UL Listing Mark

Product mark used under an applicable UL program; it covers the marked product within its certification scope.

Read more on Krayer ↗
Certification

UL Listed

Describes a product bearing an applicable UL Listing Mark; it does not automatically list the complete machine.

Read more on Krayer ↗
Certification

UL Recognized Components

Recognized components are intended for use subject to conditions of acceptability; recognition does not certify the complete panel.

Read more on Krayer ↗
Certification

Panel Shop Program

Program allowing participating panel shops to apply the UL mark to eligible panels built under program requirements.

Read more on Krayer ↗
Certification

UL Customer File / E-File

UL file identifier connecting a manufacturer with categories and scope; Krayer reports E474762 for NITW.

Read more on Krayer ↗
Certification

CCN (Category Code Number)

UL category code identifying the product type and related certification scope.

Read more on Krayer ↗
Certification

NITW

UL product category for industrial control panels; Krayer lists E474762 for this category.

Read more on Krayer ↗
Certification

NRBX

UL category for certain industrial control panels related to hazardous locations; Krayer lists E510490.

Read more on Krayer ↗
Certification

NNNY

UL category for industrial control panels and assemblies used in hazardous locations; Krayer lists E516256.

Read more on Krayer ↗
Certification

CSA C22.2 No. 286 Certification

Product certification under the applicable CSA C22.2 No. 286 program and scope; marks only apply to covered products.

Read more on Krayer ↗
Certification

NRTL

Nationally Recognized Testing Laboratory, recognized by OSHA for specified testing and certification scopes.

Browse Krayer Wiki ↗
Electrical engineering

SCCR

Short-Circuit Current Rating: a panel’s short-circuit current withstand rating determined under applicable requirements.

Read more on Krayer ↗
Electrical engineering

Industrial Control Panel

Assembly of industrial control, protection and switching components in an industrial control panel.

Read more on Krayer ↗
Electrical engineering

Industrial Control Panel Enclosure

Enclosure housing a control panel; selection depends on environment, construction and applicable approvals.

Read more on Krayer ↗
Electrical engineering

Disconnect Switch

Disconnecting device for electrical isolation; selection, location and marking depend on the installation and rules.

Read more on Krayer ↗
Electrical engineering

Interlock

Mechanical or electrical interlock enforcing specified switching or access conditions.

Read more on Krayer ↗
Electrical engineering

Field Wiring

Wiring connecting the control panel with external equipment at the installation site.

Read more on Krayer ↗
Electrical engineering

Grounding

Grounding and protective bonding to reduce electrical hazards; implementation must follow applicable requirements.

Read more on Krayer ↗
Electrical engineering

Control Panel Markings

Required panel markings and electrical ratings; they must correspond to the product and certification scope.

Read more on Krayer ↗
Electrical engineering

Wiring Diagram

Electrical diagram forming a basis for construction, inspection and maintenance.

Browse Krayer Wiki ↗
Electrical engineering

Low-Voltage Limited Energy Circuit

Circuit with limited voltage and energy; the applicable standard determines the exact classification.

Read more on Krayer ↗
Electrical engineering

Surge Protection Device

Device for limiting transient overvoltages, selected to suit the electrical installation.

Browse Krayer Wiki ↗
U.S. compliance

AHJ

Authority Having Jurisdiction: the competent authority responsible for acceptance at the actual installation location.

Read more on Krayer ↗
U.S. compliance

Field Evaluation

Separate on-site assessment of an individual product; a Field Evaluated Label is not a UL Listing Mark.

Read more on Krayer ↗
U.S. compliance

Pre-Field Evaluation

Preliminary assessment before on-site acceptance; does not replace the AHJ’s subsequent decision.

Read more on Krayer ↗
U.S. compliance

Field Labeling

Marking resulting from a separate field evaluation; it is not equivalent to a UL Listing Mark.

Read more on Krayer ↗
U.S. compliance

Hazardous Locations

Classified hazardous locations; equipment requirements depend on material and zone or division classification.

Read more on Krayer ↗
U.S. compliance

Class / Division

U.S. classification of hazardous locations by material and likelihood of presence; equipment selection must match.

Read more on Krayer ↗
U.S. compliance

HazLoc

Abbreviation for hazardous locations: classified areas requiring suitable equipment.

Read more on Krayer ↗
U.S. compliance

Explosion protection

Measures for avoiding ignition hazards; North American location classifications must be considered for the project.

Read more on Krayer ↗
U.S. compliance

UL Product iQ

UL database for researching product listings, categories, manufacturers and published certification details.

Browse Krayer Wiki ↗

This glossary is introductory and does not replace a project-specific technical assessment. Full articles are available in the Krayer knowledge center. Some linked detailed articles are currently published in German.

Discuss a UL project ↗
Project inquiry

Your inquiry for a UL 508A or CSA C22.2 No. 286 project.

Specify the destination market, application and project phase. Technical documents help Krayer prepare the discussion of relevant UL and CSA C22.2 No. 286 requirements.

Would you prefer to speak directly?
Krayer Systemtechnik GmbH
Eugen-Hahn-Straße 41 · 73565 Spraitbach
+49 7176 99 888 - 0
vertrieb@krayer.de
01 Project02  Kontakt03 Documents

What is your project about?

A few details help Krayer prepare for your inquiry.

✓

Your email draft is ready.

Your email application will open a draft including project and contact data. Review the draft and add attachments before sending.