{"id":12725,"date":"2024-03-19T15:41:00","date_gmt":"2024-03-19T14:41:00","guid":{"rendered":"https:\/\/b3v39j.myrdbx.io\/ul-wissen\/ul-wiki\/nec-500-explosion-protection\/"},"modified":"2026-07-31T19:57:30","modified_gmt":"2026-07-31T17:57:30","slug":"nec-500-explosion-protection","status":"publish","type":"wiki","link":"https:\/\/krayer.de\/en\/ul-wissen\/ul-wiki\/nec-500-explosion-protection\/","title":{"rendered":"NEC 500 \u2013 Explosion Protection"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><strong>Article 500 of the National Electrical Code<\/strong> (NEC 500) defines the classification of hazardous locations based on the type and severity of the explosion hazard.<\/p>\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n <div class=\"brlbs-cmpnt-container brlbs-cmpnt-content-blocker brlbs-cmpnt-with-individual-styles\" data-borlabs-cookie-content-blocker-id=\"youtube-content-blocker\" data-borlabs-cookie-content=\"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\"><div class=\"brlbs-cmpnt-cb-preset-c brlbs-cmpnt-cb-youtube\"> <div class=\"brlbs-cmpnt-cb-thumbnail\" style=\"background-image: url('https:\/\/krayer.de\/wp-content\/uploads\/borlabs-cookie\/1\/yt_QIJQYzTJ9RY_hqdefault.jpg')\"><\/div> <div class=\"brlbs-cmpnt-cb-main\"> <div class=\"brlbs-cmpnt-cb-play-button\"><\/div> <div class=\"brlbs-cmpnt-cb-content\"> <p class=\"brlbs-cmpnt-cb-description\">You are currently viewing a placeholder content from <strong>YouTube<\/strong>. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.<\/p> <a class=\"brlbs-cmpnt-cb-provider-toggle\" href=\"#\" data-borlabs-cookie-show-provider-information role=\"button\">More Information<\/a> <\/div> <div class=\"brlbs-cmpnt-cb-buttons\"> <a class=\"brlbs-cmpnt-cb-btn\" href=\"#\" data-borlabs-cookie-unblock role=\"button\">Unblock content<\/a> <a class=\"brlbs-cmpnt-cb-btn\" href=\"#\" data-borlabs-cookie-accept-service role=\"button\" style=\"display: inherit\">Accept required service and unblock content<\/a> <\/div> <\/div> <\/div><\/div>\n<\/div><\/figure>\n\n<h2 id=\"explosionsgefahrdete-bereiche-nach-dem-nec-500\" class=\"wp-block-heading\">Potentially Explosive Areas According to NEC 500<\/h2>\n\n<p class=\"wp-block-paragraph\">The <strong>NEC 500<\/strong> is the fundamental reference for the installation of electrical equipment in <a href=\"https:\/\/krayer.de\/en\/ul-wissen\/ul-wiki\/potentially-explosive-area\/\" data-type=\"wiki\" data-id=\"1303\">areas at risk of explosion ( <\/a>known in the U.S. as <em>\u201cHazardous Locations\u201d<\/em> or <a href=\"https:\/\/krayer.de\/en\/ul-wissen\/ul-wiki\/hazloc\/\"><em>HazLoc<\/em><\/a> ). It divides these areas into three<strong> classes<\/strong> based on <strong>the severity of the explosion hazard<\/strong> and the <strong>type of hazard source<\/strong>. Classes I and II are further subdivided into a total of six <strong>explosion groups<\/strong>, which are determined by the ignition temperature of the substances. There is no further subdivision for Class III.   <\/p>\n\n<h3 class=\"wp-block-heading\">Class I of the NEC 500<\/h3>\n\n<p class=\"wp-block-paragraph\">This class includes all <strong>flammable or explosive gases and vapors<\/strong>, such as hydrogen, acetylene, propane, or methane. This class is subdivided into <strong>Groups A, B, C, and D<\/strong>. Explosive gases can pose a significant hazard, which is why the safety regulations for HazLoc areas where they may be present are the most stringent. Class II of the NEC Code   <\/p>\n\n<p class=\"wp-block-paragraph\">Class II includes all <strong>combustible dusts<\/strong>, which are further subdivided into subcategories E (metal dusts), coal dusts (F), and grain dusts (G). According to the NEC, any particles with a diameter of no more than 420\/500 microns are generally considered dusts.     <\/p>\n\n<h3 class=\"wp-block-heading\">Class III &#8211; Fibers and Lint<\/h3>\n\n<p class=\"wp-block-paragraph\">All <strong>particles larger than 420\/500 microns<\/strong> are considered fibers or lint and fall into Class III; these include, for example, paper and cotton fibers, as well as larger wood particles.<\/p>\n\n<h2 class=\"wp-block-heading\">NEC Code \u2013 It is not always possible to clearly distinguish between classes<\/h2>\n\n<p class=\"wp-block-paragraph\">While an explosive gas generally cannot exist simultaneously as solid particles, it is possible for many solids to have individual <strong>particles<\/strong> ranging in size from over 420\/500 microns to below that threshold. Consequently, particles of Classes II and III are often present simultaneously; in such cases, the area is classified into the <strong>higher hazard class<\/strong>, i.e., Class II. <\/p>\n\n<p class=\"wp-block-paragraph\">\t\t<div data-elementor-type=\"container\" data-elementor-id=\"12627\" class=\"elementor elementor-12627 elementor-10849\" data-elementor-post-type=\"elementor_library\">\n\t\t\t\t<div class=\"elementor-element elementor-element-583d9e7d red-diamond-left e-con-full e-flex e-con e-parent\" data-id=\"583d9e7d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-1945e052 e-con-full foto e-flex e-con e-child\" data-id=\"1945e052\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2d282b64 elementor-widget elementor-widget-heading\" data-id=\"2d282b64\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Questions about UL?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3129aa26 elementor-widget elementor-widget-text-editor\" data-id=\"3129aa26\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Our experts are here to help you, whether you need a quick answer or detailed information. <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1a80b7b0 e-con-full e-flex e-con e-child\" data-id=\"1a80b7b0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-410efe7d elementor-widget elementor-widget-button\" data-id=\"410efe7d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/krayer.de\/en\/contact\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t<span class=\"elementor-button-icon\">\n\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-arrow-right\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M190.5 66.9l22.2-22.2c9.4-9.4 24.6-9.4 33.9 0L441 239c9.4 9.4 9.4 24.6 0 33.9L246.6 467.3c-9.4 9.4-24.6 9.4-33.9 0l-22.2-22.2c-9.5-9.5-9.3-25 .4-34.3L311.4 296H24c-13.3 0-24-10.7-24-24v-32c0-13.3 10.7-24 24-24h287.4L190.9 101.2c-9.8-9.3-10-24.8-.4-34.3z\"><\/path><\/svg>\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Get in touch<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-575c39ec elementor-align-end elementor-widget__width-initial elementor-mobile-align-start elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"575c39ec\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"tel:00497176998880\">\n\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"16\" height=\"16\" fill=\"currentColor\" class=\"bi bi-arrow-right\" viewBox=\"0 0 16 16\" style=\"\"><path fill-rule=\"evenodd\" d=\"M1.885.511a1.745 1.745 0 0 1 2.61.163L6.29 2.98c.329.423.445.974.315 1.494l-.547 2.19a.678.678 0 0 0 .178.643l2.457 2.457a.678.678 0 0 0 .644.178l2.189-.547a1.745 1.745 0 0 1 1.494.315l2.306 1.794c.829.645.905 1.87.163 2.611l-1.034 1.034c-.74.74-1.846 1.065-2.877.702a18.634 18.634 0 0 1-7.01-4.42 18.634 18.634 0 0 1-4.42-7.009c-.362-1.03-.037-2.137.703-2.877L1.885.511z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">+49 7176 99 888 - 0<\/span>\n\t\t\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-68ca4c83 elementor-align-end elementor-widget__width-initial elementor-mobile-align-start elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"68ca4c83\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"mailto:office@krayer.de\">\n\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"16\" height=\"16\" fill=\"currentColor\" class=\"bi bi-arrow-right\" viewBox=\"0 0 16 16\"><path d=\"M.05 3.555A2 2 0 0 1 2 2h12a2 2 0 0 1 1.95 1.555L8 8.414.05 3.555ZM0 4.697v7.104l5.803-3.558L0 4.697ZM6.761 8.83l-6.57 4.027A2 2 0 0 0 2 14h12a2 2 0 0 0 1.808-1.144l-6.57-4.027L8 9.586l-1.239-.757Zm3.436-.586L16 11.801V4.697l-5.803 3.546Z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">office@krayer.de<\/span>\n\t\t\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<\/p>\n\n<h3 class=\"wp-block-heading\">Division I and II &#8211; Explosive atmospheres classified according to the NEC Code are divided into two categories<\/h3>\n\n<p class=\"wp-block-paragraph\">The NEC 500 further subdivides <a href=\"https:\/\/krayer.de\/en\/ul-wissen\/ul-wiki\/hazardous-locations\/\" data-type=\"blog\" data-id=\"1525\">hazardous locations<\/a> into <strong>two divisions<\/strong>; however, these divisions are not based on the properties of the flammable substances, but rather on the <strong>likelihood of an explosive atmosphere occurring<\/strong>. All areas in which there is a risk of explosion under <strong>normal conditions<\/strong> \u2014whether continuously or only occasionally\u2014belong to Division I. If, on the other hand, the risk of explosion occurs only under <strong>unusual conditions<\/strong> (such as technical malfunctions or operator errors), the area is classified as Division II. <\/p>\n\n<h3 class=\"wp-block-heading\">Division or Ex-Zone: What&#8217;s the Difference?<\/h3>\n\n<p class=\"wp-block-paragraph\">In addition to the classification of explosive atmospheres just discussed, the NEC also provides for a further subdivision into various <a href=\"https:\/\/krayer.de\/en\/ul-wissen\/ul-blog\/what-types-of-ex-zones-are-there\/\"><strong>explosion zones<\/strong><\/a> (see NEC 505). Explosion zones <strong>focus on the frequency of occurrence of a potentially explosive atmosphere<\/strong>, whereas the exact definition of the combustible substance takes a back seat. A distinction is made only between gases and mists on the one hand and dusts on the other.  <\/p>\n\n<p class=\"wp-block-paragraph\"><strong>Division I<\/strong> therefore corresponds to Ex Zones 0 and 20, as well as 1 and 21, as defined in Articles 505 and 506 of the NEC, respectively, while <strong>Division II<\/strong> corresponds to Zone 2 and 22, respectively.<\/p>\n\n<figure class=\"wp-block-image size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1920\" height=\"540\" src=\"https:\/\/krayer.de\/wp-content\/uploads\/2024\/03\/HazLoc-zertifizierter-Steuerschrank-1920x540.webp\" alt=\"Hazloc NNNY + NRBX\" class=\"wp-image-2952\" title=\"The NEC Code: Legal Standard for Hazardous Locations\" srcset=\"https:\/\/krayer.de\/wp-content\/uploads\/2024\/03\/HazLoc-zertifizierter-Steuerschrank-1920x540.webp 1920w, https:\/\/krayer.de\/wp-content\/uploads\/2024\/03\/HazLoc-zertifizierter-Steuerschrank-768x216.webp 768w, https:\/\/krayer.de\/wp-content\/uploads\/2024\/03\/HazLoc-zertifizierter-Steuerschrank-300x84.webp 300w, https:\/\/krayer.de\/wp-content\/uploads\/2024\/03\/HazLoc-zertifizierter-Steuerschrank-1536x432.webp 1536w, https:\/\/krayer.de\/wp-content\/uploads\/2024\/03\/HazLoc-zertifizierter-Steuerschrank-2048x576.webp 2048w\" sizes=\"(max-width: 1920px) 100vw, 1920px\" \/><\/figure>\n\n<h2 id=\"was-bedeutet-der-nec-500-fur-den-betrieb-elektrischer-anlagen-in-nordamerika\" class=\"wp-block-heading\">What does the NEC 500 mean for the operation of electrical systems in North America?<\/h2>\n\n<p class=\"wp-block-paragraph\"><strong>At first glance, NEC 500 provides only a definition<\/strong> of hazardous locations. From this perspective, it only becomes relevant to explosion protection <strong>in conjunction with articles of the <\/strong>National Electrical Code, such as <a href=\"https:\/\/krayer.de\/en\/ul-wissen\/ul-wiki\/nec-504\/\">NEC 504<\/a>, which deals specifically with the installation of intrinsically safe systems. It also relates to <a href=\"https:\/\/krayer.de\/en\/ul-wissen\/ul-wiki\/nfpa-79\/\">NFPA 79<\/a> and other standards that define protection classes, specific requirements for equipment and their enclosures, and much more.  <\/p>\n\n<p class=\"wp-block-paragraph\">Nevertheless, the few requirements set forth in NEC 500 are of <strong>the utmost importance<\/strong> for German equipment manufacturers who export to the United States or Canada, as they ensure that their products can be put into service there.<\/p>\n\n<h3 class=\"wp-block-heading\">The NEC 500 and Its Significance for Export Business to the U.S.<\/h3>\n\n<p class=\"wp-block-paragraph\">The requirements that NEC 500 imposes on equipment are very general. <strong>Section 500.8<\/strong> merely requires that the equipment be suitable for use in the respective class, group, and temperature class and be marked accordingly. Above all, two mistakes must be avoided:  <\/p>\n\n<ol class=\"wp-block-list\">\n<li>The <strong>temperature class<\/strong> should not be confused with the explosion group; they are two different things.<\/li>\n\n\n\n<li>The <strong>ATEX marking<\/strong> used in Europe in accordance with DIN EN ISO 80079-36 \/-37 is not recognized in the United States.<\/li>\n<\/ol>\n\n<p class=\"wp-block-paragraph\">In <strong>Canada<\/strong>, the Canadian Electrical Code (CEC) is a codified system that is fully consistent with that of the NEC 500; consequently, CSA markings are recognized in the United States.<\/p>\n\n<p class=\"wp-block-paragraph\"><h2 class=\"wp-block-heading\"><strong>Zusammenfassung<\/strong><\/h2><p class=\"wp-block-paragraph\"><\/p>\n\n<p class=\"wp-block-paragraph\"><strong>Article 500 of the National Electrical Code (NEC 500)<\/strong> is the legal standard in effect in the United States for defining hazardous locations. It competes with the Ex-zone classification specified in <a href=\"https:\/\/krayer.de\/en\/ul-wissen\/ul-wiki\/nec-505\/\">NEC 505<\/a>. Both articles only become relevant in practice in conjunction with more detailed provisions of the NEC or <a href=\"https:\/\/krayer.de\/en\/ul-wissen\/ul-wiki\/nfpa-79\/\" data-type=\"wiki\" data-id=\"1750\">NFPA 79<\/a>, as well as other regulations, some of which are influenced by the in-house standards of UL or CSA.  <\/p>\n\n<p class=\"wp-block-paragraph\"><\/p><\/p>\n","protected":false},"author":4,"featured_media":12727,"template":"","categories":[163],"tags":[166,170,164,177],"class_list":["post-12725","wiki","type-wiki","status-publish","has-post-thumbnail","hentry","category-ul-wiki","tag-csa","tag-ex-area","tag-ul","tag-united-states"],"_links":{"self":[{"href":"https:\/\/krayer.de\/en\/wp-json\/wp\/v2\/wiki\/12725","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/krayer.de\/en\/wp-json\/wp\/v2\/wiki"}],"about":[{"href":"https:\/\/krayer.de\/en\/wp-json\/wp\/v2\/types\/wiki"}],"author":[{"embeddable":true,"href":"https:\/\/krayer.de\/en\/wp-json\/wp\/v2\/users\/4"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/krayer.de\/en\/wp-json\/wp\/v2\/media\/12727"}],"wp:attachment":[{"href":"https:\/\/krayer.de\/en\/wp-json\/wp\/v2\/media?parent=12725"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/krayer.de\/en\/wp-json\/wp\/v2\/categories?post=12725"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/krayer.de\/en\/wp-json\/wp\/v2\/tags?post=12725"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}